Sankey and Chord charts are two complementary visualization approaches for making complex system relationships visible. Sankey emphasizes the quantity and magnitude of flow transferred from a source to a destination, while Chord reveals the intensity of relationships and interactions between components in a circular structure.
Sankey charts show the source β transformation β destination path of flows such as energy, mass, cost, or data together with the magnitude of the flow. The most distinctive characteristic is that the thickness of the flow line is proportional to the quantity being transferred.
Objective: Make visible the stages at which hydraulic energy is lost during its conversion into electrical energy.
Flow: Reservoir potential energy β hydraulic losses β turbine mechanical energy β mechanical losses β generator electrical energy β electrical losses β energy delivered to the grid.
Total alarms β operator intervention β alarm reset β downtime β maintenance β recurring alarm
This view analyzes not only the number of alarms, but also what outcomes they lead to and whether they recur after intervention.
Failure types β downtime duration β energy loss (MWh)
This makes it possible to evaluate failure frequency together with generation loss. Gate failures that occur infrequently but cause long downtime can become critical through this approach.
Mechanical maintenance β vibration reduction β efficiency increase
Hydraulic maintenance β oil alarms β gate response time
This helps relate maintenance activities not only to their duration, but also to the operational indicators they affect.
Low / medium / high flow β normal / load following / operation under alarm conditions β alarm types
An increase in flow thickness associated with vibration or cavitation alarms under high-flow conditions can provide a technical indication for reviewing operating limits.
Unit-1 / Unit-2 / Unit-3 β mechanical / hydraulic / electrical problems β corresponding maintenance type
This makes it possible to identify characteristic problem clusters by unit and see how they translate into maintenance activities.
Morning startup β alarm β intervention β downtime β maintenance β restart
Chord charts show mutual relationships and interactions between components within a circular structure. Unlike Sankey, the primary focus is not one-way flow quantity, but relationship intensity and many-to-many connections.
Mechanical maintenance β vibration alarms
Hydraulic maintenance β oil temperature alarms
Electrical maintenance β related electrical alarm groups
This analysis helps visually evaluate the relationship between maintenance activities and reductions in alarm behavior. Thus, it is possible to examine not only whether maintenance was βperformed,β but also which problem it affected and to what extent.
Low flow / medium flow / high flow β cavitation / vibration / overheating / alarm-downtime
A dominant Unit-2 β hydraulic chord may indicate that the characteristic problem of the corresponding unit is concentrated around the hydraulic system.
| Feature | Sankey | Chord | EOS SCADA Example |
|---|---|---|---|
| Primary focus | Flow quantity | Relationship / interaction | Energy flow / alarm relationship |
| Structure | Source β destination | Circular nodes | Energy chain / subsystem network |
| Thickness | Transferred quantity | Relationship intensity | MWh / alarm / frequency |
| Strongest question | How much went where? | Who is related to whom? | Loss / root cause |
| HPP example | Water β electricity β loss | Alarm β subsystem | Efficiency / maintenance / alarm analysis |