Temperature
Can be used to monitor the temperature of a furnace, boiler, process line, tank, or machine within a defined operating range.
LB_GOSTERGE provides an analog indicator that displays a process value on a circular scale using a needle. The scale, graduations, and needle work together to allow a numerical value to be read quickly and visually.
The indicator's colors and visual properties are configurable. The scale color, needle color, and other display settings can be changed through the control's properties. Therefore, the control can be adapted to different SCADA screen designs and to the display requirements of different process values.
This type of indicator is particularly useful on process screens where operators need to assess the current value, value range, and position of the value on the scale at a glance.
LB_GOSTERGE can be used to monitor continuously changing analog process values quickly and intuitively on a circular scale. It is particularly suitable for SCADA screens where operators need to easily recognize the position of a value within a defined minimum and maximum range. Its applications are not limited to a specific process variable; its scale and needle properties can be adapted to display different analog values.
Can be used to monitor the temperature of a furnace, boiler, process line, tank, or machine within a defined operating range.
Provides a quick and intuitive display of analog values such as line, tank, or equipment pressure.
Can be used to monitor the position of a liquid or gas flow rate within the process operating range on a circular scale.
Can be used to present continuous analog variables such as electrical power and load ratio visually to the operator.
Suitable for displaying analog values such as rotational speed and velocity in motors, pumps, turbines, and similar equipment.
Can serve as a general-purpose analog indicator for various continuous process variables with defined minimum and maximum limits.
LB_GOSTERGE is designed as an analog display indicator, not as a setting or control element. As the value arrives from the controller or connected data source, the indicator updates and moves the needle to the position corresponding to the new value.
The primary purpose of this control is to visualize an analog value. It should not be used to issue operator commands or adjust a process variable. If such functionality is required, an appropriate control with authorization and command management should be used instead.
Min Value and Max Value define the analog measurement range represented by the indicator. This range establishes the lower and upper limits of the scale over which the needle moves.
| Property | Function |
|---|---|
| Min Value | Defines the lower limit of the indicator scale. |
| Max Value | Defines the upper limit of the indicator scale. |
| Scale Divisions | Defines the arrangement of graduations on the main scale. |
| Scale Subdivisions | Defines the arrangement of smaller scale marks between the main divisions. |
LB_GOSTERGE is configured through a small number of properties that directly affect the visual reading experience. This allows the control to be easily reconfigured for different process variables.
| Property | Value | Description |
|---|---|---|
| Control Type | LB_GOSTERGE | Specifies the type of the user control. |
| Update Interval | 1000 ms | Specifies the data update interval of the indicator. |
| Decimal Places | 0 | Defines the number of decimal places used when displaying numerical values. |
| Control Background Color | Transparent | Defines the background color of the control. |
| Control Foreground Color | Red | Defines the text color of the control. |
| Control Font | Arial Narrow 6.75 | Defines the font used within the control. |
| Min Value | 0 | Defines the minimum value of the scale. |
| Max Value | 100 | Defines the maximum value of the scale. |
| Scale Color | White | Defines the color of the circular scale. |
| Scale Subdivisions | 10 | Defines the number of minor marks between scale divisions. |
| Scale Divisions | 11 | Defines the number of major scale divisions. |
| Needle Color | Yellow | Defines the color of the needle indicating the current value. |
The same indicator structure can be used with different engineering units. The key consideration is to ensure that the Min Value and Max Value range is appropriate for the actual process range.
| Process Variable | Example Scale | Visual Purpose |
|---|---|---|
| Temperature | 0–200 °C | Quickly read the position of the current temperature within the operating range. |
| Pressure | 0–16 bar | Monitor the pressure level on an analog dial. |
| Flow Rate | 0–100 m³/h | See the current position of the flow rate. |
| Rotational Speed | 0–3000 rpm | Monitor machine speed using an analog indicator. |
| Load Ratio | 0–100% | Display the load level on a percentage scale. |
Minimum and maximum values should meaningfully represent the actual process operating range.
Maintain sufficient visual contrast between the needle, scale, and background, and avoid making the indicator too small.
For important process values, the circular indicator can be supplemented with a numerical value or unit information when necessary.
LB_GOSTERGE brings the conventional circular dial appearance to EOS SCADA screens and provides an alternative for quickly reading analog process values through the relationship between the scale and needle position.
Properties such as Min Value, Max Value, Scale Color, Scale Subdivisions, Scale Divisions, and Needle Color allow the same basic indicator to be adapted to different process variables.
Numerical process value → circular scale → needle position → rapid visual interpretation.